Total Access 5000 Business Services Deployment Guide
4-24 65K510DEP08-1A
Create an EVC Map
Thissubsectiondetailsthefollowing information:
Definitionofamap
•Stepsforcreatingamap
•Stepsforconfiguringamap
•Mapexample
Map Definition
DefinetheassociationofcustomertrafficonaUNIportwithanEVCbydefininganentity
calledanEVCmap.EachEVCmapisty picallyassociatedwithasinglecustomerand
specifiesparametersincludingthecustomerVLANIDandClassofService(CoS)behaviorof
thetrafficfromthecustomer.
UseamaptoclassifytrafficforusebyanEVCforforwarding
andforusebyapolicerforratelimiting.
Map Guidelines
Toensurevalidprovisioning,enforcethefollowingguidelineswhencreatingamap:
•AmapisappliedonlyiftheEVCmap’sstatusisRunning(asindicatedintheshowevc
mapoutput),whichindicatesthattheconditionsarevalid
•Twomapsareconsideredtobeduplicateiftheybothhavethesame
valuesforthe
followingattributes:
–UNIport
–CEVLANID
–OverlappingrangeforCEVLAN Pri
DifferentiatedServicesCodePoint(DSCP)value
Untaggedprioritytaggedframes
•Notwomapscanhavethesamename
•IfthesystemismanagedthroughaVLANonadesignatedbondinggrouporEthernet
port,themanagementVIDvalue
cannotequaltheCEVLANIDvalueofthemap
•IftheCEVLANIDpreservationattributeofanEVCisdisabled,allof themapsconnected
totheEVCmusthavethesamevalueoftheCEVLANIDattributewhichcanincludenot
specifyingthis attributewhichallowsmeans
theEVCmapdoesnotconsiderVLANID
initsmatchcriteria
•WhenmultiplemapsareappliedtoasingleEVC,eachmapmusthavethesameUNI.
MultipleUNIscannotbe mappedtoasingleEVC
•IftwoormoremapshaveeitherthesameUNIorthesameassociated
EVC,onlyoneof
themapscanbeprovisionedtoallowuntaggedandprioritytaggedframes

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.