EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #176 background imageLoading...
Page #176 background image
Total Access 5000 Business Services Deployment Guide
6-20 65K510DEP08-1A
Create an EVC Map
Thissectiondetailsthefollowinginformation:
Definitionofamap
•Stepsforcreatingamap
•Stepsforconfiguringamap
•Mapexample
Map Definition
DefinetheassociationofcustomertrafficonaUNIportwithanEVCbydefininganentity
calledanEVCmap.EachEVCmapisty picallyassociatedwithasinglecustomerand
specifiesparametersincludingthecustomerVLANIDandClassofService(CoS)behaviorof
thetrafficfromthecustomer.
UseamaptoclassifytrafficforusebyanEVCforforwarding
andforusebyapolicerforratelimiting.
Map Guidelines
Toensurevalidprovisioning,enforcethefollowingguidelineswhencreatingamap:
•AmapisappliedonlyiftheEVCmap’sstatusisRunning(asindicatedintheshowevc
mapoutput),whichindicatesthattheconditionsarevalid
•Twomapsareconsideredtobeduplicateiftheybothhavethesame
valuesforthe
followingattributes:
–UNIport
–CEVLANID
–OverlappingrangeforCEVLAN Pri
DifferentiatedServicesCodePoint(DSCP)value
Untaggedprioritytaggedframes
•Notwomapscanhavethesamename
•IfthesystemismanagedthroughaVLANonadesignatedbondinggrouporEthernet
port,themanagementVIDvalue
cannotequaltheCEVLANIDvalueofthemap
•IftheCEVLANIDpreservationattributeofanEVCisdisabled,allof themapsconnected
totheEVCmusthavethesamevalueoftheCEVLANIDattribute
•WhenmultiplemapsareappliedtoasingleEVC,each
mapmusthavethesameUNI.
MultipleUNIscannotbe mappedtoasingleEVC
•IftwoormoremapshaveeitherthesameUNIorthesameassociatedEVC,onlyoneof
themapscanbeprovisionedtoallowuntaggedandprioritytaggedframes

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.