Total Access 5000 Business Services Deployment Guide
5-12 65K510DEP08-1A
Create an EVC Cross Connect
Thissubsectiondetailsthefollowing information:
DefinitionofanEVC
•GuidelinesforcreatinganEVC
•StepsforcreatinganEVC
EVC Definition
AnEVCisalogicalenti tythatprovidesameansforconnectingtwoendpointsintheTotal
Access5000andprovidesapathforEthernetframeswithaparticularVLANIDwithinthe
TotalAccess5000. TheEVCcrossconnectstwoendpointsandprovidesthemechanismby
whichanStag
pathiscreatedinthesystem.TheStagcorrespondstotheVLANID.
IntheTotalAccess5000,customertrafficswitchesthroughoutthesystemviaStags
(outermostVLANtagonanEthernetpacket).Downstreamtrafficentersthesystemthrough
thenetworkportsontheGigESMandisS
tagswitchedtotheappropriateslotandPPP
group.
TheMetroEthernetForum(MEF)definesanEVCas“anassociationoftwoormoreUNIs,”
whereaUNIisastandard10/100/1000 Ethernetinterfacethatisthepointofdemarcation
betweenthe CustomerEquipment(CE)andtheMetroEthernetNetwork(MEN)
oftheservice
provider.Insimpleterms,anEVCperformstwofunctions.
Connectstwoormoresubscribersites(UNIs)enablingthetransferofEthernetservice
frames
•PreventsdatatransferbetweenthesubscribersitesthatarenotpartofthesameEVC
ThiscapabilityenablesanEVCtoprovidedataprivacyandsecurity
similartoaFrame
RelayorATMPermanentVirtualCircuit(PVC).
EachEVCtypicallyhasanassociatedEVCVLANtagwhoseVLANIDisuniqueamongother
EVCsintheMEN.TheEVCVLANtagallowstheEVCtobeidentifiedandseparatedfrom
otherEVCs.
Ataminimum,twoitems
mustbesetupfortheEVC:theMENinterfaceitwilluseandthe
Stagitwilluse.
TheEVCspecifiestowhichserviceproviderVLANthenewPPPgroupinterfaceistied.Italso
specifiesthefollowing:
•TheupstreamMetroEthernetNetwork(MEN)ports:a GigabitEthernetporton
theGigE
SM,oraGigElinkaggregationgroup
•TheserviceproviderVLAN(stag)

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.