Admin State
ThisattributeistheuserconfigurablestateoftheEVCmap.TableF7liststheavailable
options.
UNI
ThisattributeisthephysicalinterfaceconnectedtotheCustomerEquipment(CE)or
subscriber.ItisthedemarcationpointofAdtranequipmenttothesubscriberpremisesandis
thegatewayintotheEVC.TheprotectionoftheEVCisperformedattheUNIsothatassump
tionscanbemadewithin
theEVC.
CE-VLAN-ID
ThisattributeistheVLANIDoftheoutermostVLANtagoftheEthernetframereceivedatthe
UNIport.Ifthevalueisunspecified,thentheEVCmapappliestotheremainderofcustomer
framesreceivedthatarenotaffectedbyotherEVCmapsonthesameUNIport.
CE-VLAN-Pri
ThisattributeisarangeofPbitvaluesoftheoutermostVLANtagoftheEthernetframe
receivedattheUNIport.ThisattributecanonlybespecifiediftheDSCPattributeisnot
specified.ThevalueisenteredasacharacterstringoftheallowablePbitvalues.
OverlapsSystemmanagement
evc
TheCEVLANIDconflictswiththeVIDthatisactivelyusedfor
managingthesystemandthetwoaresharingthesameport..
Preserveconflict TheEVCisnotpreservingCEVLANIDandhasatleasttwo
EVCmapsconnectedtoitwithdifferentvaluesfortheCE
VLANIDattribute.ForanEVCforwardingtrafficintheMEN
toUNIdirection,theswitchusestheCEVLANIDvalueofthe
EVCmap.Thereisnowayfortheswitchtodeterminewhat
valuetoapplyifthevaluesvaryacrossconnectedEVCmaps.
OverlapsEVC TheUNIoftheEVCmapisusedbyaMENportofanenabled
EVC.
Table F-7. Map State Options
Option Definition
Enabled TheEVCmapisinservice,andtheprovisioningisappliedifthe
conditionsarevalid.
Disabled TheEVCmapisnotinservice,andtheprovisioningisnot
applied.
Table F-6. EVC Map Status Values (Continued)
Possible Value Definition

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.