EasyManuals Logo

ADTRAN Total Access 5000 Deployment Guide

ADTRAN Total Access 5000
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
Total Access 5000 Business Services Deployment Guide
3-26 65K510DEP08-1A
Configure the Password Complexity
Passwordcomplexity providesoptionsthatincreaseordecreasethelevelofpasswordsecurity
byadjustingspecificlocalpasswordrequirements.Bydefault,passwordcomplexityis
disabled,placingnorestrictionsonpasswordscreatedforlocalaccounts.Toenablepassword
complexity,completethef ollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
security,andpressENTERtoaccessthe
SecurityConfigurationprompt.
3. FromtheSecurityConfigurationprompt,type
password complexity,andpressENTER.
4. Type
end,andpressENTERtoreturntotheEnableprompt.
Oncecompleted,thefollowingoptionscanbeenabledordisabled.Toenable,simplyenterthe
commandasshown.Todisable,typenopasswordcomplexityfromtheSecurityConfigu
rationprompt.
TheoptionslistedinTable37areenabledordisabledattheSecurityConfiguration
prompt.
Table 3-7. Password Complexity Options
CLI Command Description
case-sensitive
Ifenabled,allusernamesandpasswordsarecasesensitive.
password digit
Ifenabled,itrequiresallpasswordstocontainatleastonenumeric
character.
password length
<min_length>
Setstheminimumlengthofthepassword.
password lowercase
Ifenabled,itrequiresallpasswordstohaveatleastoneuppercase
alphabetcharacter.
password no-digit-
start-end
Ifenabled,passwordscannotstartorendwithanumericcharacter.
password special
Ifenabled,itrequiresallpasswordstohaveatleastoneuppercase
alphabetcharacter.
password uppercase
Ifenabled,itrequiresallpasswordstohaveatleastoneuppercase
alphabetcharacter.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.

Related product manuals