Section 5, BSM Provisioning - Provision the Line Module
65K510DEP08-1A 5-5
2. FromtheGlobalConfigurationprompt,provisionthemoduleadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotakeaslotInService
•Type
slot shutdown maintenance <shelf/slot>,andpressENTERtotakeaslot
OutofServiceMaintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotakeaslotOutofService,
Unassigned
3. FromtheGlobalConfigurationprompt,type
interface t3 <shelf/slot/
port:channel>
,andpressENTER.
4. FromtheT3InterfaceConfigurationprompt,type
description LINE,andpressENTER
toconfiguretheCircuitID.
5. FromtheT3InterfaceConfigurationprompt,type
framing [cbit|m23],andpress
ENTERtoselecttheframingmode.
6. FromtheT3InterfaceConfigurationprompt,provisiontheT3portadministrationstate
byperformingoneofthefollowingcommands:
•Type
no shutdown,andpressENTERtotakeaportInService
•Type
shutdown maintenance,andpressENTERtotakeaportOutofServiceMainte
nance
•Type
shutdown,andpressENTERtotakeaportOutofServiceUnassigned
7. Repeatsteps36foreachDS3portthatneedstobeprovisioned.
8. FromtheT3InterfaceConfigurationprompt,type
exit,andpressENTERtoreturntothe
GlobalConfigurationprompt.
9. FromtheGlobalConfigurationprompt,type
interface t1 <shelf/slot/port>,and
press
ENTER.
10. FromtheT1InterfaceConfigurationprompt,type
description LINE,andpressENTER
toconfiguretheCircuitID.
11. FromtheT1InterfaceConfigurationprompt,type
framing [d4|esf],andpressENTER
toselecttheframingmode.
12. FromtheT1InterfaceConfigurationprompt,provisiontheT1portadministrationstate
byperformingoneofthefollowingcommands:
•Type
no shutdown,andpressENTERtotakeaportInService
•Type
shutdown maintenance,andpressENTERtotakeaportOutofService,Mainte
nance
•Type
shutdown,andpressENTERtotakeaportOutofService,Unassigned
13. Type
end,andpressENTERtoreturntotheEnableprompt.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.