Section 6, EoTDM Provisioning - Provision the Line Module
65K510DEP08-1A 6-5
•ToaccesstheDS3EFM4Port,typeinterface t3 <shelf/slot/port>,and
press
ENTER.
•ToaccesstheDS3EFM3Port,type
interface t3 <shelf/slot/
port:channel>
,andpressEnter.
4. ToconfiguretheCircuitID,type
description LINE,andpressENTER.
5. ProvisiontheDS3portadministrationstatebyperformingoneofthefollowing
commands:
•Type
no shutdown,andpressENTERtotaketheportInService
•Type
shutdown maintenance,andpressENTERtotaketheportOutofService,
Maintenance
•Type
shutdown,andpressENTERtotaketheportOutofService,Unassigned
6. Tosetthealarmthresholds,type
thresholds [cvc-p|cv-l|cvp-p|
escp-p|es|esp-p|sefs-p|sescp-p|uas-p] [15 minute|24 hour]
<0-4294967295>
,andpressENTER.
7. Repeatsteps38foreachDS3portthatneedstobeprovisioned.
8. Type
end,andpressENTERtoreturntotheEnableprompt.