Appendix C, Ethernet OAM Provisioning - Ethernet OAM on the NetVanta 800/8000 Series NCTE
65K510DEP08-1A C-7
SingletagCFMserviceforstag100:
Component1VLAN100DownMEPontheMENport
Component1VLAN100UpMEPontheUNIdefinedbyanEVCmapconnectedto
theEVCwithstag100
SingletagCFMserviceforctag20towards customer:
Component2VLAN
20DownMEPontheUNIportforcustomerCFMservice
operability.
DoubletagCFMserviceforstag100,ctag20destinedfor aProvidernetwork:
Component2VLAN20UpMEPontheUNIportdefinedbyanEVCmapconnected
totheEVCwithstag100
9. Type
exit,andpressENTER toreturntotheMDprompt.
10. Type
exit,andpressENTER toreturntotheGlobalConfigurationprompt.
11. AMIPcanbecreatedonaspecificVIDandspecific MDlevelbyenteringtheDefault
MD.TheMIPwillbecreatedonallMENportswiththatVIDsolongthataDownMEP
onthesameVIDdoesn’texistata
equalorhigherlevel.
12. FromtheGlobalConfigurationprompt,entertheEthernetCFMDefaultMDbytyping
ethernet cfm default-domain,andpressENTER.
13. FromtheDefaultMDComponentprompt,type
component 1 vlan <2-4094>,and
press
ENTERtoconfiguretheMIPcreationsettingsforthespecifiedProviderVLAN.
AprerequisiteforeditingaDefaultMDComponentisthattheVLANmustalreadybe
definedbyaEVCusingthesamestagandintheRunningstate.IfnosuchEVCexists,
thentheMIPrulescannot
beaccessedforthatDefaultMDComponentVID.
14. FromtheDefaultMDComponentprompt,type
level <0-7>,andpressENTER.TheMIP
creationwillbeattemptedatthespecifiedMDlevelforthisProviderVID.
15. FromtheDefaultMDComponentprompt,type
mip-allowed any,andpress ENTERto
allowMIPstobecreatedonthisProviderVID.
16. Type
exit,andpressENTERtoreturntotheGlobalConfigurationprompt.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.