Total Access 5000 Business Services Deployment Guide
3-20 65K510DEP08-1A
2. FromtheGlobalConfigurationprompt,typetacacs-server host A.B.C.D key
WORD port <1-65535> timeout <1-30>
,andpressENTERtoconfiguretheTACACS+
server.
NOTE
Anycombinationofshared_key, port_num, andtimeout_secscanbe
specified,including listingnoneofthematall. On lytheparameters
specifiedwillbechange dfromtheglobalTACACS+defaultvalu es(or
whatevertheircurrentvaluesare).
IftheIP addressistha tofanewTACACS+server,anewserverwill
be
addedtotheTACACS+serverlist.Allserverparameterswillbedefaulted
tothe global TA CACS+va l u e , andthenoverwrittenwithwhichever
parametersarespecifiedaftertheIPaddress.Iftheserverisanexisting
server,theparametersspecifiedwillbemodified.
3. Type
tacacs-server host A.B.C.D name WORD,andpressENTERtosettheTACACS+
serverhostname.
4. Tosettheserversequencenumber(orpriority),type
tacacs-server host A.B.C.D
sequence-number <0-4>
,andpressENTER,wherepriority=1(primaryserver),2,
(secondaryserver),andsoonupto4.
NOTE
Only0canhavemulitpleservers.Sequencenumbers 1‐4canonlyhaveone
serverforeachsequencenumberatanygiventime.Toswapthesequence
numberoftwoservers,temporarilysetthesequencenumberofoneserverto
0,ch angetheother serverssequencenumber,andthenchangethe sequence
numberofthefirstserverfrom0tothenewdesirednumber.
Ifthesequencenumberisnotspecified,thesystemautomaticallyorderstheservers
(fromprimaryondown)astheyareentered,sothespecificationofthesequencenumber
isonlynecessaryifthepriorityorderneedstobechanged.
Aserverwithasequence
numberofzeroiseffectivelydisabled.
5. TodeleteaTACACS+serverfromtheserverlist,type
no tacacs-server host
A.B.C.D
,andpressENTER.

Table of Contents

Other manuals for ADTRAN Total Access 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 5000 and is the answer not in the manual?

ADTRAN Total Access 5000 Specifications

Interfaces IconInterfaces
craft interfaceDB-9 RS-232 Electrical Interface (Async)
admin interfaceDB-9 RS-232 DTE Electrical Interface (Async with Modem Control Signals)
network management portDB-9 RS-232 DTE Electrical Interface (Async)
ethernet interface10Bt
external alarm inputs16
Operating Environment IconOperating Environment
operating temperature-40°C to +65°C
storage temperature-40°C to +70°C
relative humidityUp to 95%, non-condensing
Weight and Dimensions IconWeight and Dimensions
height9.25 in.
width0.08 in.
depth9.5 in.
weight0.6 lbs.