Replacing an ECM
Next, reconnect the ECM-3 cables, as required.
b. When using the CEM port, set the IPaddress and subnet mask for the ECM-3
bridge0 interface.
set dcn dcn-interface bridge0 169.254.0.62/24
13. Transfer the ECMfile from the NCU RAM to the ECM-3 staging area.
execute dbmgt db-copy-from remote-file <ECM filename> ftp
169.254.0.33 <user_id>
Press <Enter> and then enter the password when prompted.
14. Validate and copy the backed up database from staging area to active DB area.
execute dbmgt restore-db
15. Select one of these actions, based on the system response:
o
If the system returns "Success. - all OK," activate the database.
execute dbmgt activate
The ECM-3 will reset with the new database. You will lose connectivity to the
node when the ECM-3 resets.
o
If the system returns "Success. SLOT-ID mismatch," the backed up database is
from the same shelf (same shelf serial number), but a different slot ID. Accept the
IDmismatch.
execute dbmgt accept-id-mismatch
You will lose connectivity to the node when the ECM-3 resets. After the reset, the
ECM-3 operates with the restored database.
o
If the system returns "Success. SHELF-SERIAL mismatch," the backed up
database is from a shelf with a different shelf serial number. Repeat Step 13
through Step 15 with the correct database file.
o
If the system returns any of these error responses, repeat Step 13 through Step
15 with the correct database file.
o
"Restore Database failed. SHELF-UHI mismatch," means that the backed up
database is for the wrong shelf type.
o
"Restore Database failed. CRC validation failed," means that the backed up
database is corrupted.
o
"Restore Database failed. Unable to get backup-IDs from database
metadata," means that the backed up database format is not supported.
16. Remove the USB to RJ-45 cable.
17. If required, reconnect the ECM-3 cables.
18. Look at the module LEDs to ensure they are operating correctly. For
LEDinformation, see Troubleshooting with Component LEDs.
FSP 3000R7 High-Density Subshelf Guide - R17.2 - Issue:B 418