Variable Value
<activate> Specifies the AES on time.
<deactivate> Specifies the AES off time.
monday|tuesday|wednesday |
thursday|friday|saturday|
sunday
Configures AES scheduling for a specific
day.
<hh:mm> Specifies
the scheduled AES start time (hour
and minutes).
weekday Configures AES scheduling for all
weekdays.
weekend Configures AES scheduling for Saturday and
Sunday.
Disabling AES scheduling using ACLI
Use the following procedure to discontinue using an on and off time interval for the switch to
enter lower power states.
Prerequisites
• Log on to the Global Configuration mode in ACLI.
• Disable AES globally.
Procedure steps
Configure AES scheduling by using the following command:
no energy-saver schedule
Variable definitions
The following table defines optional parameters that you can enter after the no energy-
saver schedule command.
Variable Value
friday|monday|saturday|
sunday| thursday|tuesday|
wednesday
Disables AES scheduling for a specific day.
System configuration using ACLI
204 Configuration — System April 2011