Variable Value
SynchInterval Specifies the frequency, in hours, that the device
attempts to synchronize with the NTP servers.
V
alues range from 0 to 168. With a value of 0,
synchronization occurs only when the switch boots
up.
ManualSyncRequest
Specifies that the device to immediately attempt to
synchronize with the NTP servers.
LastSyncTime Indicates the Coordinated Universal Time (UTC)
when the device last synchronized with an NTP
server. This is a read-only value.
LastSyncSourceInetAddress Type Indicates the IP source address type of the NTP
server with which this device last synchronized.
LastSyncSourceInetAddress Indicates the IP source address of the NTP server
with which this device last synchronized. This is a
read-only value.
NextSyncTime Indicates the UTC at which the next synchronization
is scheduled.
PrimaryServerSyncFailures Indicates the number of times the switch failed to
synchronize with the primary server address.
However, synchronization with the secondary server
address can still occur.
SecondaryServerSyncFailures
Indicates the number of times the switch failed to
synchronize with the secondary server address,
CurrentTime Indicates the current switch UTC.
Configuring the local time zone using EDM
Use the following procedure to set a local time zone.
Procedure steps
1. From the navigation tree, double-click Edit
.
2. In the Edit tree, double-click SNTP/Clock.
3. In the work area, click theTime Zone tab.
4. In the TimeZone box, select the time zone offset.
Configuring the local time zone using EDM
Configuration — System April 2011 277