Variable definitions
Use the data in the following table to add coordinate-based location information for the remote
device.
Field Description
Latitude Specifies the latitude in degrees, and its
relation to the equator (North or South).
Longitude Specifies the longitude in degrees, and its
relation to the prime meridian (East or
West).
Altitude Specifies the altitude, and the units of
measurement used (meters or floors).
Map Datum Specifies the map reference datum. V
alues
include:
WGS84—World Geodesic System 1984,
Prime Meridian Name: Greenwich
NAD83/NAVD88—North American Datum
1983/ North American Vertical Datum of
1988
NAD83/MLLW—North American Datum
1983/ Mean Lower Low Water
Viewing local PoE PSE information using EDM
Use this procedure to display LLDP PoE PSE information for the local system.
Procedure steps
1.
From the navigation tree, double-click Edit.
2. In the Edit tree, double-click Diagnostics.
3. In the Diagnostic tree, double-click 802.1AB.
4. In the 802.1AB tree, double-click Port MED.
5. On the work area, click the Local PoE PSE tab.
Variable definitions
The following table describes the Local PoE PSE tab fields.
LLDP Port MED configuration using EDM
Configuration — System April 2011 323