Adding ELIN based device location information using EDM
Use this procedure to add information to the local location table for remote network devices
connected to a switch or stack, based on an Emergency Location Information Number
(ELIN).
Procedure steps
1. From the navigation tree, double-click Edit
.
2. In the Edit tree, double-click Diagnostics.
3. In the Diagnostic tree, double-click 802.1AB.
4. In the 802.1AB tree, double-click Port MED.
5. On the work area, click the Local Location tab.
6. In the port row with elin as the location subtype, double-click the cell in the
LocationInfo column.
7. Type an alphanumeric value from 10 to 25 characters in length.
8. Click Apply .
Adding coordinate and civic address based device location information using
EDM
Use this procedure to add local location information to the local location table for remote
network devices connected to a switch or stack, based on geographical coordinates and a civic
address.
Procedure steps
1. From the navigation tree, double-click Edit.
2. In the Edit tree, double-click Diagnostics.
3. In the Diagnostic tree, double-click 802.1AB.
4. In the 802.1AB tree, double-click Port MED.
5. On the work area, click the Local Location tab.
6. To add location information based on geographical coordinates for the remote
device, click the coordinateBased cell in the LocationSubtype column for a port.
7. To add location information based on the civic address for the remote device, click
the civicAddress cell in the LocationSubtype column for a port.
8. Click Location Detail.
9. Insert the local location information for the remote device.
10. Click Ok .
11. Click Apply .
System configuration using Enterprise Device Manager