Chapter 8: Configuration reference
The sections in this chapter provide information on the factory default configuration.
Factory default configuration
When you
initially access a newly installed switch or you reset a switch to factory defaults, the
switch is in a factory default configuration. This factory default configuration is the base
configuration from which you build the switch configuration.
Table 93: Factory default configuration settings on page 357 outlines the factory default
configuration settings present in a switch in a factory default state.
Table 93: Factory default configuration settings
Setting Factory default configuration value
Unit Select switch non-Base
Unit 1
BootP Request Mode BootP When Needed
In-Band Stack IP Address 0.0.0.0 (no IP address assigned)
In-Band Switch IP Address 0.0.0.0 (no IP address assigned)
In-Band Subnet Mask 0.0.0.0 (no subnet mask assigned)
Default Gateway 0.0.0.0 (no IP address assigned)
Read-Only Community String public
read/write Community String private
Trap IP Address 0.0.0.0 (no IP address assigned)
Community String Zero-length string
Authentication Trap Enabled
Autotopology Enabled
sysContact Zero-length string
sysName Zero-length string
sysLocation Zero-length string
Aging Time 300 seconds
Configuration — System April 2011 357