Variable Value
Type Indicates whether the banner type is for a standalone (switch)
or a stack (stack).
Id Indicates the line of text within a custom banner.
Line Specifies the banner character string. The custom banner is 19
lines high and can be up to 80 characters long.
Configuring AUR using EDM
Use this procedure to configure automatic unit replacement (AUR).
Procedure steps
1. From the navigation tree, double-click Edit
.
2. In the Edit tree, double-click Chassis.
3. In the Chassis tree, double-click Chassis.
4. In the work area, select the AUR tab.
5. To enable automatic unit replacement, select the AutoUnitReplacementEnabled
check box.
OR
To disable automatic unit replacement, clear the AutoUnitReplacementEnabled
check box.
6. To enable automatic unit replacement save, select the
AutoUnitReplacementSaveEnabled check box.
OR
To disable automatic unit replacement save, clear the
AutoUnitReplacementSaveEnabled check box.
7. In the AutoUnitReplacementForceSave dialog box, type a value.
8. In the AutoUnitReplacementRestore dialog box, type a value.
9. Click Apply .
System configuration using Enterprise Device Manager
226 Configuration — System April 2011