Avaya 4526FX - Viewing Poe for Multiple Switch Units Using EDM

Avaya 4526FX
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variable Value
pethMainPowerUsageOnNotification trap. If the power
consumption exceeds
and then falls below the threshold, the switch
sends the pethMainPowerUsageOffNotification trap.
Important:
You must enable the traps (NotificationControlEnable) to receive
a power usage trap.
Notification
ControlEnable
Lets you enable or disable sending traps if the switch power usage
exceeds the percentage set in the UsageThreshold field.
PowerDevice
DetectType
Lets you set the power detection type that the switch uses to detect
a request for power from a device connected to all ports on the
switch:
802.3af
802.3af and legacy
Important:
The default setting is 802.3af. Ensure that this setting matches
the setting for the detection type used by the powered devices
on this switch.
PowerPresent Specifies the currently used power source. Available power
sources are AC and DC.
A value of acOnly indicates that the only power supply is AC.
A value of dcOnly indicates that the only power supply is DC.
A value of acDc indicates that there are two power supplies; both
AC and DC are supplying power
Viewing PoE for multiple switch units using EDM
Use this procedure to display the PoE configuration for one or more switches in a stack.
Procedure steps
1. From the navigation tree, double-click Power Management
.
2. In the Power Management tree, double-click PoE.
3. In the work area, click the Globals - PoE Units tab.
Switch unit PoE management using EDM
Configuration — System April 2011 217