Name / value range / [default setting]
Trigger signal for releasing the holding brake (TRUE = release holding
brake).
Note!
If this trigger is assigned to the relay or a digital output, the deceleration
times set for the respective output are not effective (are internally set to
"0"). Only the deceleration time set in 0x2820:012 (P712.12) for closing
the holding brake influences in this case the time-dependent behaviour
of the output.
Holding brake control
302
(P420.25)
Digital outputs function: NetWordOUT1 bit 15
(Dig.out.function: NetWordOUT1.15)
For further possible settings, see parameter
0x2634:001 (P420.01).
429
Assignment of a trigger to bit 15 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
Safe torque off (STO) active
TRUE if the integrated safety system has triggered the "Safe torque off
(STO)" function. Otherwise FALSE.
Inversion of digital outputs: NetWordOUT1.00
Inversion of bit 0 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.01
Inversion of bit 1 of NetWordOUT1.
0x2635:012
Inversion of digital outputs: NetWordOUT1.02
Inversion of bit 2 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.03
Inversion of bit 3 of NetWordOUT1.
1
Inverted
Inversion of digital outputs: NetWordOUT1.04
Inversion of bit 4 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.05
Inversion of bit 5 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.06
Inversion of bit 6 of NetWordOUT1.
0x2635:017
Inversion of digital outputs: NetWordOUT1.07
Inversion of bit 7 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.08
Inversion of bit 8 of NetWordOUT1.
1
Inverted
Inversion of digital outputs: NetWordOUT1.09
Inversion of bit 9 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.10
Inversion of bit 10 of NetWordOUT1.
Inversion of digital outputs: NetWordOUT1.11
Inversion of bit 11 of NetWordOUT1.
0x2635:022
Inversion of digital outputs: NetWordOUT1.12
Inversion of bit 12 of NetWordOUT1.