Brake system
P-9
2. Start the engine and step down the brake pedal when the vacuum degree achieved 66.7kPa{500mmHg}.
If the fluid pressure is within the specified range, it means that the brake device is in normal operation.
Pedal pressure
Fluid pressure
MTX
196N
{20kgf}
7100kPa{72kgf/cm
2
}min
ATX
8820kPa{90kgf/cm
2
}min
Removal/installation of vacuum booster
1. Remove the brake master cylinder
(See——Conventional brake system,
Removal/installation of brake master cylinder).
2. Remove in the order as shown in the Table.
3. Assembly in the reversing order of disassembly.
1 Vacuum booster hose assembly
2 Spring pin
3 Axle pin
4 Nut
5 Vacuum booster pump
6 Check valve assembly