Basic system
U-7
Disassembling and assembling of blower
evaporator assembly
1. disassemble in order as shown in the table.
2. assemble in reverse order as of disassembly.
1 Air intake housing
2 Internal & external air damper connecting rod
3 Internal & external air damper actuator
4 Internal & external air damper assembly
5 H expansion valve
6 Blower evaporator upper housing
7 Evaporator element
8 Thermistor
9 Blower evaporator upper housing
10 Speed regulation module assembly
11 Motor throttle duct
12 Blower motor assembly
A/c compressor removal/installation
1. disconnect the negative battery cable.
2. drain refrigerant from the system.
3. remove the mudguard.
4. loosen the drive belt and remove it.
Attention
If moisture or impurity enters the cooling
recirculation system, cooling ability will be reduced
and abnormal noise will occur. Always plug all open
fittings immediately after removing any cooling
recirculation system component to keep moisture or
impurity out of the system.
Do not allow a/c compressor oil to flow out. If the
a/c compressor operates in lack of oil, abnormal
noise and scuffing of a/c compressor will occur.
5. remove in order as shown in the table.
6. install in reverse order as of removal.
7. adjust the drive belt.
8. perform the cooling system performance test.
1 High-pressure pipe assembly (high pressure)
2 Pipe subassembly (low pressure)
3 Connector
4 A/c compressor