Generator and Starter
19
Generator and starter
Lubrication system of Engine
Warning
l When disassembling/assembling a generator on the CBU, you should remove
first the battery cable, otherwise the terminal B of generator will get in touch
with the bodywork , cause sparks and result in personnel injury and electrical
component damage.
1. Disassemble as per the order shown in Fig.
2. Assemble in the reversing order of disassembly.
3. Check the deflection /tension of belt (See——Engine belt, Check of Engine Belt).
1
Generator
2
Alternator belt
Check of engine belt
1. When necessary, check the deflection and tension of engine belt.
Deflection check of engine belt
Attention
l The belt deflection shall be checked in 30mins after the engine cooled down or
shut down.
1. Appropriate pressure of 98N{10kgf, 22lbf} is to be added between two pulleys.
l If the deflection is out of the specified scope, adjust the engine belt (See——
Adjustment of Engine Belt).
Limit value: 10mm {0.39in}