Anti-lock brake system (ABS control unit)
P-27
E
Close the exhaust screw
F
Release the brake pedal
G
Check the travel of pedal
H
If failed, repeat the air exhaust
J
Check the level of brake liquid, and assure that it is kept between the max. and min.
levels.
4. Exhaust by artificial pedal in combination with the exhaust by filling unit
A
Connect the exhaust/filling unit to the liquid storage tank, confirm that there is
sufficient braking liquid to turn on the switch. Set up the pressure to 200bars
B
Repeat the following procedure to exhaust the air in each wheel cylinder.
Sequence: left rear; left front; right front and right rear.
B1
Repeatedly step the brake pedal
C
Check the travel of pedal
D
If failed, repeat the exhaust of every wheel
E
Check the level of brake liquid and assure that it is kept between the max. and min.
levels.
Remark:
The recommended sequence for X loop: left rear, left front, right front and right rear
If decreasing the pressure before opening the screw. The correct grade of filling is normally set
automatically
During the whole exhaust process, the brake fluid in the tank (container) cannot be lower than the lowest
scale.
5. Artificial exhaust diagram
Artificial exhaust diagram of X-loop of 4-way ABS control unit: left front wheel