Troubleshooting
U-40
Step Inspection Action
*14
Inspect continuity of wiring harness between
temperature sensor and refrigerant pressure
switch.
l Turn ignition switch to lock position.
l Inspect continuity between following
temperature sensor terminals (a/c signal)
and refrigerant pressure switch terminal.
(gy engine) terminal c
Terminal c
l Is there continuity?
Yes Go to next step.
No Repair wiring harness between
refrigerant pressure switch and
temperature sensor, then go to step 28.
*15
Inspect continuity of wiring harness between
front climate control unit and temperature
sensor
l Is there continuity between front climate
control unit terminal i and temperature
sensor terminal b?
Yes Replace front climate control unit
No Repair wiring harness between front
climate control unit and temperature
sensor.
*16
Verify whether malfunction is in pcm and
wiring harness (continuity between pcm and
refrigerant pressure switch) or elsewhere.
l Turn ignition switch to on position.
l Measure voltages of following refrigerant
pressure switch connector terminals (at
wiring harness side)
(gy engine) terminal a.
l Is voltage approximately equivalent to b+
(positive battery voltage)?
Yes Go to steps 18.
No Go to next step.
*17 Verify whether malfunction is in pcm or
wiring harness (pcm and refrigerant pressure
switch)
l Measure voltage at pcm terminal 41 (a/c
signal).
l Is voltage approximately equivalent to b+
(positive battery voltage)?
Yes Repair wiring harness between pcm and
refrigerant pressure switch, then go to
step 28.
No Inspect pcm, then go to step 28.
*18
Verify whether malfunction is in refrigerant
pressure switch or elsewhere.
l When following refrigerant pressure switch
connector terminals (at wiring harness
side) are short, does cold air blow out?
(gy engine) terminal a.
Terminal c.
Yes Inspect refrigerant pressure switch, then
go to step 28.
No Disconnect shorted circuit and reconnect
refrigerant pressure switch terminal, go
to next step.