EasyManua.ls Logo

Keysight Technologies InfiniiVision MSO-X 4022A

Keysight Technologies InfiniiVision MSO-X 4022A
1580 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1178 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
33 :TRIGger Commands
:TRIGger:GLITch:SOURce
(see page 1428)
Command Syntax
:TRIGger:GLITch:SOURce <source>
<source> ::= {DIGital<d> | CHANnel<n>}
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :TRIGger:GLITch:SOURce command selects the channel that produces the
pulse width trigger.
Query Syntax
:TRIGger:GLITch:SOURce?
The :TRIGger:GLITch:SOURce? query returns the current pulse width source. If all
channels are off, the query returns "NONE".
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 1139
":TRIGger:MODE" on page 1148
":TRIGger:GLITch:LEVel" on page 1174
":TRIGger:GLITch:POLarity" on page 1175
":TRIGger:GLITch:QUALifier" on page 1176
":TRIGger:GLITch:RANGe" on page 1177
Example Code "Example Code" on page 1169