698 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
26 :POWer Commands
:POWer:SIGNals:SOURce:CURRent<i>
(see page 1428)
Command Syntax
:POWer:SIGNals:SOURce:CURRent<i> <source>
<i> ::= 1, 2 in NR1 format
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels) in NR1 format
The :POWer:SIGNals:SOURce:CURRent<i> command specifies the first, and
perhaps second, current source channel to be used in the power analysis.
Query Syntax
:POWer:SIGNals:SOURce:CURRent<i>?
The :POWer:SIGNals:SOURce:CURRent<i> query returns the current source
channel setting.
Return Format
<source><NL>
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels) in NR1 format
See Also ":POWer:SIGNals:AUTosetup" on page 681
":POWer:SIGNals:CYCLes:HARMonics" on page 682
":POWer:SIGNals:CYCLes:QUALity" on page 683
":POWer:SIGNals:DURation:EFFiciency" on page 684
":POWer:SIGNals:DURation:MODulation" on page 685
":POWer:SIGNals:DURation:ONOFf:OFF" on page 686
":POWer:SIGNals:DURation:ONOFf:ON" on page 687
":POWer:SIGNals:DURation:RIPPle" on page 688
":POWer:SIGNals:DURation:TRANsient" on page 689
":POWer:SIGNals:IEXPected" on page 690
":POWer:SIGNals:OVERshoot" on page 691
":POWer:SIGNals:VMAXimum:INRush" on page 692
":POWer:SIGNals:VMAXimum:ONOFf:OFF" on page 693
":POWer:SIGNals:VMAXimum:ONOFf:ON" on page 694
":POWer:SIGNals:VSTeady:ONOFf:OFF" on page 695
":POWer:SIGNals:VSTeady:ONOFf:ON" on page 696
":POWer:SIGNals:VSTeady:TRANsient" on page 697
":POWer:SIGNals:SOURce:VOLTage<i>" on page 699