646 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
26 :POWer Commands
:POWer:HARMonics:LINE
(see page 1428)
Command Syntax
:POWer:HARMonics:LINE <frequency>
<frequency> ::= {F50 | F60 | F400 | AUTO}
The :POWer:HARMonics:LINE command specifies the line frequency setting for the
current harmonics analysis:
F50 — 50 Hz.
F60 — 60 Hz.
F400 — 400 Hz.
AUTO — Automatically determines the frequency of the Current waveform.
Query Syntax
:POWer:HARMonics:LINE?
The :POWer:HARMonics:LINE query returns the line frequency setting.
Return Format
<frequency><NL>
<frequency> ::= {F50 | F60 | F400 | AUTO}
See Also ":POWer:HARMonics:APPLy" on page 642
":POWer:HARMonics:DATA" on page 643
":POWer:HARMonics:DISPlay" on page 644
":POWer:HARMonics:FAILcount" on page 645
":POWer:HARMonics:POWerfactor" on page 647
":POWer:HARMonics:RUNCount" on page 650
":POWer:HARMonics:STANdard" on page 651
":POWer:HARMonics:STATus" on page 652