926 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:SENT:TRIGger:SLOW:ID
(see page 1428)
Command Syntax
:SBUS<n>:SENT:TRIGger:SLOW:ID <id>
<id> ::= when ILENgth = SHORt, from -1 (don't care) to 15, in NR1 format
.
<id> ::= when ILENgth = LONG, from -1 (don't care) to 255, in NR1 format
.
The :SBUS<n>:SENT:TRIGger:SLOW:ID command specifies the ID to trigger on for
the "Slow Channel Message ID" and "Slow Channel Message ID & Data" trigger
modes. The ID can be from -1 (don't care) to 255 (depending on the message
length).
Query Syntax
:SBUS<n>:SENT:TRIGger:SLOW:ID?
The :SBUS<n>:SENT:TRIGger:SLOW:ID? query returns the slow channel ID setting.
Return Format
<id><NL>
<id> ::= when ILENgth = SHORt, from -1 (don't care) to 15, in NR1 format
.
<id> ::= when ILENgth = LONG, from -1 (don't care) to 255, in NR1 format
.
See Also ":SBUS<n>:SENT:CLOCk" on page 900
":SBUS<n>:SENT:CRC" on page 901
":SBUS<n>:SENT:DISPlay" on page 902
":SBUS<n>:SENT:FORMat" on page 904
":SBUS<n>:SENT:IDLE" on page 906
":SBUS<n>:SENT:LENGth" on page 907
":SBUS<n>:SENT:PPULse" on page 908
":SBUS<n>:SENT:SIGNal<s>:DISPlay" on page 909
":SBUS<n>:SENT:SIGNal<s>:LENGth" on page 910
":SBUS<n>:SENT:SIGNal<s>:MULTiplier" on page 912
":SBUS<n>:SENT:SIGNal<s>:OFFSet" on page 913
":SBUS<n>:SENT:SIGNal<s>:ORDer" on page 914
":SBUS<n>:SENT:SIGNal<s>:STARt" on page 916
":SBUS<n>:SENT:SOURce" on page 918
":SBUS<n>:SENT:TOLerance" on page 920
":SBUS<n>:SENT:TRIGger" on page 921
":SBUS<n>:SENT:TRIGger:FAST:DATA" on page 923
":SBUS<n>:SENT:TRIGger:SLOW:DATA" on page 924

Table of Contents