:SBUS<n> Commands 29
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 767
:SBUS<n>:A429:FORMat
(see page 1428)
Command Syntax
:SBUS<n>:A429:FORMat <format>
<format> ::= {LDSDi | LDSSm | LDATa}
The :SBUS<n>:A429:FORMat command specifies the word decode format:
•LDSDi:
Label - 8 bits.
SDI - 2 bits.
Data - 19 bits.
SSM - 2 bits.
LDSSm:
Label - 8 bits.
Data - 21 bits.
SSM - 2 bits.
•LDATa:
Label - 8 bits.
Data - 23 bits.
Query Syntax
:SBUS<n>:A429:FORMat?
The :SBUS<n>:A429:FORMat? query returns the current ARINC 429 word decode
format setting.
Return Format
<format><NL>
<format> ::= {LDSD | LDSS | LDAT}
Errors "-241, Hardware missing" on page 1387
See Also "Introduction to :SBUS<n> Commands" on page 755
":SBUS<n>:MODE" on page 759
":SBUS<n>:A429:TRIGger:PATTern:DATA" on page 772
":SBUS<n>:A429:TRIGger:PATTern:SDI" on page 773
":SBUS<n>:A429:TRIGger:PATTern:SSM" on page 774
":SBUS<n>:A429:TRIGger:TYPE" on page 776
":SBUS<n>:A429:SIGNal" on page 768
":SBUS<n>:A429:SPEed" on page 770
":SBUS<n>:A429:BASE" on page 763