:TRIGger Commands 35
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 1351
:TRIGger:OR
(see page 1610)
Command Syntax
:TRIGger:OR <string>
<string> ::= "nn...n" where n ::= {R |F|E|X}
R = rising edge, F = falling edge, E = either edge, X = don't care.
The :TRIGger:OR command specifies the edges to include in the OR'ed edge
trigger.
In the <string> parameter, each bit corresponds to a channel as described in the
following table:
Query Syntax
:TRIGger:OR?
The :TRIGger:OR? query returns the current OR'ed edge trigger string.
Return Format
<string><NL>
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":TRIGger:MODE" on page 1308
Oscilloscope Models Value and Mask Bit Assignments
4 analog + 16 digital channels (mixed-signal) Bits 0 through 15 - digital channels 0 through
15. Bits 16 through 19 - analog channels 4
through 1.
2 analog + 16 digital channels (mixed-signal) Bits 0 through 15 - digital channels 0 through
15. Bits 16 and 17 - analog channels 2 and 1.
4 analog channels only Bits 0 through 3 - analog channels 4 through 1.
2 analog channels only Bits 0 and 1 - analog channels 2 and 1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision MSO-X 4022A and is the answer not in the manual?

Keysight Technologies InfiniiVision MSO-X 4022A Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision MSO-X 4022A
CategoryTest Equipment
LanguageEnglish