1186 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
33 :TRIGger Commands
:TRIGger:NFC:TIMeout
(see page 1428)
Query Syntax
:TRIGger:NFC:TIMeout?
The :TRIGger:NFC:TIMeout? query returns whether the timeout occurred.
With the ATRigger (Arm & Trigger) trigger event, if the second event does not
occur within the timeout period, the oscilloscope triggers when the timeout period
expires.
A return value of 1 says the desired trigger event did not occur within the specified
time after the arm event.
A return value of 0 says the desired trigger event occurred before the timeout.
Return Format
<timeout_occurred><NL>
{0 | 1}
See Also • ":TRIGger:NFC:AEVent" on page 1180
• ":TRIGger:NFC:ATTime" on page 1181
• ":TRIGger:NFC:SOURce" on page 1182
• ":TRIGger:NFC:STANdard" on page 1183
• ":TRIGger:NFC:TEVent" on page 1184
• ":TRIGger:NFC:TIMeout:ENABle" on page 1187
• ":TRIGger:NFC:TIMeout:TIME" on page 1188