Adjusting Sensor B9/B10 Bale Firmness (Comprima CF155 XC):
HDC00033
7
Fig. 124
Caution!
The bale chamber must be closed and empty.
If the bar (1) is not inside the rectangle (2) when the bale chamber is closed and emptied, the
corresponding sensor (7) must be adjusted mechanically.
To do this:
• Loosen the sensor (7) and turn it in the oblong hole until the bar (1) is positioned inside the
rectangle (2) of the bar display.
Note
An audio signal sounds if the bar (1) is inside the rectangle (2).
Saving Value:
• Press function key until the symbol appears briefly in the upper line .
Note
The value is saved when the left bar has accepted the value of the right bar.