2JZ/2JX/2JV/2H7-1
1-3-65
U128
Setting transfer high-voltage timing
Description
Adjusts the ON/OFF timing of transfer high-voltage output.
Purpose
Basically, the setting need not be changed. If any problem such as faulty images or dirt on the back surface
occurs, change the setting.
Method
1. Press the start key.
2. Select the item to set.
3. Change the value using the +/- or numeric keys.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U130
Initial setting for the developing unit
Description
Replenishes toner to each developing unit to a certain level from the respective color toner container that has
been installed.
Purpose
To perform when installing the machine or replacing the developing unit.
Method
1. Press the start key.
2. Select the color for which toner is replenished.
3. Press the start key.
Toner installation is started.
Completion
Press the stop key after initial setting is complete. The screen for selecting a maintenance item No. is dis-
played.
Maintenance
item No.
Description
Display Description Setting range Initial setting
Trans ON Timing1 Transfer ON timing adjustment value
(first side)
-200 to 200 -54
Trans ON Timing2 Transfer ON timing adjustment value
(second side)
-200 to 200 -54
Trans OFF Timing Transfer OFF timing adjustment value -200 to 200 10
Display Description
BLACK Toner is replenished to black developing unit
CYAN Toner is replenished to cyan developing unit
MAGENTA Toner is replenished to magenta developing unit
YELLOW Toner is replenished to yellow developing unit