2JZ/2JX/2JV/2H7-1
1-3-81
U202
Setting the KMAS host monitoring system
Description
Initializes or operates the KMAS host monitoring system.
This is an optional device which is currently supported only by Japanese specification machines, so no setting
is necessary.
U203
Operating the DP separately
Description
Simulates the original conveying operation separately in the optional DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP if running this simulation with paper.
3. Select the item to be operated.
*: Dual scan DP only.
4. Press the start key. The operation starts.
5. To stop continuous operation, press the stop key.
Completion
Press the stop key when the operation stops. The screen for selecting a maintenance item No. is displayed.
U204
Setting the presence or absence of a key card or key counter
Description
Sets the presence or absence of the optional key card or key counter.
Purpose
To run this maintenance item if a key card or key counter is installed.
Setting
1. Press the start key.
2. Select the optional counter to be installed.
Initial setting: OFF
3. Press the start key. The setting is set.
4. Turn the main power switch off and on.
Maintenance
item No.
Description
Display Description Setting range Initial setting
CCD ADP
(NON P)
Without paper, single-sided original of CCD
(continuous operation)
--
CCD ADP With paper, single-sided original of CCD - -
CCD RADP
(NON P)
Without paper, double-sided original of CCD
(continuous operation)
--
CCD RADP With paper, double-sided original of CCD - -
CIS RADP
(NON P)*
Without paper, double-sided original of CIS
(continuous operation)
--
CIS RADP* With paper, double-sided original of CIS - -
SPEED
Switching between normal reading (600 dpi)
and high-speed reading
0 (Normal)/
1 (High-speed)
0
Display Description
KEY-CARD The key card is installed
KEY-COUNTER The key counter is installed
OFF Not installed