2JZ/2JX/2JV/2H7-1
1-5-19
(3) Detaching and refitting the ISU (reference)
Follow the procedure below to replace the ISU.
Fitting requires the following tools
Two positions pins (P/N 18568120)
Procedure
Detaching the ISU
1. Remove the contact glass (see page 1-5-
11).
2. Remove seven screws and then remove the
ISU cover.
Figure 1-5-31
3. Remove three screws and two connectors,
and then remove the ISU.
4. Replace the ISU.
Figure 1-5-32
Screws
ISU cover
Screws
Screws
Connector
Connector
Screws
Screw
ISU