2JZ/2JX/2JV/2H7-1
1-3-68
U136
Setting toner near end detection
Description
Sets the level that indicates the number of sheets that can be printed from occurrence of toner near end to
toner empty.
Purpose
To change the setting to advance detection of near end if the interval from toner near end to toner empty
seems too short.
Setting
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Increasing the setting makes the interval from toner near end to toner empty longer.
Decreasing the setting makes the interval from toner near end to toner empty shorter.
If 0 is set, toner near end will not be detected.
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U139
Displaying the temperature and humidity outside the machine
Description
Displays the detected temperature and humidity outside the machine.
Purpose
To check the temperature and humidity outside the machine.
Method
1. Press the start key. The detected temperature (
°C/°F) and humidity (%) outside the machine are dis-
played.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display Description
Setting
range
Initial
setting
BK Setting the level of black toner 0 to 9 2
CMY Setting the level of cyan/magenta/yellow toner 0 to 9 2
Display Description
External Temperature
External temperature (
°C)
External Humidity
External humidity (
%)
Internal Temp1 (LSU)
Internal temperature around the laser scanner unit (
°C)
Internal Temp2
Internal temperature around the transfer section (
°C)
Internal Temp3
Internal temperature around the developing section (
°C)