EasyManua.ls Logo

Kyocera TASKalfa 400ci - Power Source PWB Table

Kyocera TASKalfa 400ci
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2JZ/2JX/2JV/2H7-1
2-3-3
Connector Pin No. Signal I/O Voltage Description
TB
1 AC_LIVE I 120 V AC
220-240 V AC
AC power input
Connected
to the inlet
and main
power
switch
2 AC_NEUTRAL I 120 V AC
220-240 V AC
AC power input
3 HEATER LIVE - - Not used
YC1
1 MSW_IN I 120 V AC
220-240 V AC
AC power input from MSW
Connected
to the main
power
switch
2 MSW_OUT O 120 V AC
220-240 V AC
AC power input from MSW
YC2
1 DH2_LIVE O 120 V AC
220-240 V AC
AC power output to CH (option)
Connected
to the
optional
paper feeder
2 NC - - Not used
3 DH2_NEUTRAL O 120 V AC
220-240 V AC
AC power output to CH (option)
YC3
1 DH3_LIVE O 120 V AC
220-240 V AC
AC power output to CH1
Connected
to the cas-
sette heater
1/2
2 DH3_LIVE O 120 V AC
220-240 V AC
AC power output to CH2
3 NC - - Not used
4 NC - - Not used
5 DH3_NEUTRAL O 120 V AC
220-240 V AC
AC power output to CH1
6 DH3_NEUTRAL O 120 V AC
220-240 V AC
AC power output to CH2
YC4
1 H_LIVE O 120 V AC
220-240 V AC
AC power to FH1/2/3
Connected
to the fuser
heater 1/2/3
2 SH_OUT O 120 V AC
220-240 V AC
FH2: On/Off
3 PR_OUT O 120 V AC
220-240 V AC
FH3: On/Off
4 MH_OUT O 120 V AC
220-240 V AC
FH1: On/Off
YC5 1 24V1 O 24 V DC 24 V DC power to ISMPWB
Connected
to the ISM
PWB and
optional DP
2 24V1 O 24 V DC 24 V DC power to DPDPWB
3 12V1 O 12 V DC 12 V DC power to ISMPWB
4 5V1 - - Not used
5 5V1 O 5 V DC 5 V DC power to DPDPWB
6 GND - - Ground
7 GND - - Ground
8 GND - - Ground
9 GND - - Ground
10 GND - - Ground