2JZ/2JX/2JV/2H7-1
1-3-120
U464
Setting the ID correction operation
Description
Turns ID correction (calibration) on or off. Also, this determines the duration of calibration and the timing of
calibration during printing. Also, this allows individual settings for calibration operation by enabling custom set-
tings.
Purpose
To restrict calibration when poor image quality is generated. Also, this allows individual settings for calibration
by enabling custom settings in setting the calibration cycle under the machine defaults depending on the user
preferences.
Performs AC calibration when replacing the developing or drum unit.
Method
1. Press the start key.
2. Select the item to be set. The setting screen for the selected item is displayed.
Setting: [Permission]
1. Select ON or OFF.
Initial setting: ON
2. Press the start key. The setting is set.
Setting: [Set Time Interval]
1. Change the setting value using the +/- or numeric keys.
2. Press the start key. The setting is set.
Maintenance
item No.
Description
Display Description
Permission Setting to turn calibration on/off
Set Time Interval Setting the interval time of calibration after printing
Set Sleep Period for
Calib
Setting the standard time for judging whether or not to carry out calibration
based on the sleep time when the machine recovers from the sleep mode.
Permission
Act.(50sheets)
Turning paper interval calibration on/off after continuously printing 50 pages
Permission
(ON/Sleep out)
Setting execution parameters for calibration when powered up or reverted
from auto-sleep
Permission (AP/NE) Paper interval calibration ON/OFF setting at the time of calibration/near end
after toner feed
SetCalib Timing
duringPrint
Setting the standard time for judging whether or not to carry out calibration
based on the continuous print driving time during printing.
Set Interval
CalibDriveTime
Setting the standard time for judging whether or not to carry out paper inter-
val calibration based on the driving time during printing.
Set Interval
CalibPrint Rate
Setting the standard printing ratio for judging whether or not to carry out cal-
ibration based on the printing ratio when printing the tenth sheet.
Set Custom Turning custom settings on/off in setting the calibration cycle under the
machine defaults
AC Calibration Executing the AC calibration
Display Description
ON Turns calibration ON
OFF Turns calibration OFF
Display Description Setting range Initial setting
COUNT Setting the interval time of calibration 0 to 9999 (s) 480