2JZ/2JX/2JV/2H7-1
1-3-32
U053
Setting the adjustment of the motor speed
Description
Performs fine adjustment of the speeds of the motors.
Purpose
Basically, the setting need not be changed.
Modify settings by interlock setting only if faulty images occur.
Method
1. Press the start key.
2. Select the item to be adjusted.
*: 50/40 ppm model only.
Setting: [Set MOTOR1]
1. Select the item to be adjusted.
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
Setting: [Set MOTOR2]
1. Select the item to be adjusted.
*: 40/40, 50/40 ppm model only.
Maintenance
item No.
Description
Display Description
Set MOTOR1 Adjustment of drum motor M, C, Y, K speeds
Set MOTOR2 Adjustment of developing motor K, developing motor MCY, transfer
motor, polygon motor, middle motor and registration motor speeds
Set MOTOR3 Adjustment of MP motor, eject motor, job eject motor, fuser motor and
duplex motor speeds
Set MOTOR4* Drum motor K speed adjustment in black/white mode
Set MOTOR5* Adjustment of developing motor K, transfer motor, polygon motor,
middle motor and registration motor speeds in black/white mode
Set MOTOR6* Adjustment of MP motor, eject motor, job eject motor, fuser motor and
duplex motor speeds in black/white mode
Display Description Setting range Initial setting
Drum C (Full) Drum motor C (DRM-C) full speed -500 to 500 4
*1
/0
*2
Drum M (Full) Drum motor M (DRM-M) full speed -500 to 500 4
*1
/0
*2
Drum Y (Full) Drum motor Y (DRM-Y) full speed -500 to 500 4
*1
/0
*2
Drum K (Full) Drum motor K (DRM-K) full speed -500 to 500 4
*1
/0
*2
Drum C (Half) Drum motor C (DRM-C) half speed -500 to 500 0
Drum M (Half) Drum motor M (DRM-M) half speed -500 to 500 0
Drum Y (Half) Drum motor Y (DRM-Y) half speed -500 to 500 0
Drum K (Half) Drum motor K (DRM-K) half speed -500 to 500 0
Display Description Setting range Initial setting
Dev K Developing motor K (DEVM-K) -500 to 500 -351
Dev MCY Developing motor MCY (DEVM-MCY) -500 to 500 -351
TC Motor(Full) Transfer motor (TRM) full speed -500 to 500 0
TC Motor(Half) Transfer motor (TRM) half speed -500 to 500 0
Polygon(Full) Polygon motor (PM) full speed -500 to 500 0
MID Roller Motor* Middle motor (MM) -500 to 500 0
Regist Motor* Registration motor (RM) -500 to 500 0