2JZ/2JX/2JV/2H7-1
1-3-33
U053
Setting: [Set MOTOR3]
1. Select the item to be adjusted.
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
Setting: [Set MOTOR4]
1. Select the item to be adjusted.
*1: 50/40 ppm model *2: 40/40 ppm model *3: 25/25, 30/30 ppm model
Setting: [Set MOTOR5]
1. Select the item to be adjusted.
Setting: [Set MOTOR6]
1. Select the item to be adjusted.
Adjustment
1. Press the system menu key.
2. Press the start key to output an A3/Ledger test pattern.
Figure 1-3-7
Maintenance
item No.
Description
Display Description Setting range Initial setting
MPF MP motor (MPM) -500 to 500 0
Eject Motor Eject motor (EM) -500 to 500 0
OPT Eject Job eject motor (JEM) (option) -500 to 500 0
Fixing Motor Fuser motor (FUM) -500 to 500 150
*1
/0
*2
Duplex Motor Duplex motor (DUM) -500 to 500 0
Feed Motor Paper conveying motor (PCM) -500 to 500 -50
Display Description Setting range Initial setting
Drum K(Full) BW Drum motor K (DRM-K) full speed -500 to 500 17
*1
/20
*2
/27
*3
Display Description Setting range Initial setting
Dev K(BW Convey) Developing motor K (DEVM-K) -500 to 500 -178
TC Motor (F) BW Transfer motor (TRM) full speed -500 to 500 0
MID Roller Motor BW Middle motor (MM) -500 to 500 50
Regist Motor BW Registration motor (RM) -500 to 500 50
Polygon (F) BW Polygon motor (PM) full speed -500 to 500 0
Display Description Setting range Initial setting
MPT BW MP motor (MPM) -500 to 500 0
Eject Motor BW Eject motor (EM) -500 to 500 0
OPT Eject BW Job eject motor (JEM) (option) -500 to 500 0
Fixing Motor BW Fuser motor (FUM) -500 to 500 380
Duplex Motor BW Duplex motor (DUM) -500 to 500 0
Correct values for an A3/Ledger output are:
A = 350
± 0.5 mm
B = 250