2JZ/2JX/2JV/2H7-1
1-4-31
C1120 PF left lift position problem (optional
3000-sheet paper feeder)
Level switch 1 does not turn on within 30
s of PF lift motor 2 turning on.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC27 on
the engine PWB and the connector on the
PF main PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective level
switch 1.
Check if YC5-4 on the PF main PWB goes
low when level switch 1 is turned off. If not,
replace PF lift switch 1.
Defective PF lift
motor 2.
Check for continuity across the coil. If none,
replace PF lift motor 2.
The PF left lift does
not rise properly.
Check the gears and belts, and remedy if
necessary.
C1130 PF right lift position problem (optional
3000-sheet paper feeder)
Level switch 2 does not turn on within 30
s of PF lift motor 1 turning on.
Poor contact in the
connector termi-
nals.
Check the connection of connector YC27 on
the engine PWB and the connector on the
PF main PWB, and the continuity across the
connector terminals. Repair or replace if
necessary.
Defective level
switch 2.
Check if YC5-7 on the PF main PWB goes
low when level switch 2 is turned off. If not,
replace PF lift switch 2.
Defective PF lift
motor 1.
Check for continuity across the coil. If none,
replace PF lift motor 1.
The PF right lift
does not rise prop-
erly.
Check the gears and belts, and remedy if
necessary.
C1400 Rotary guide motor error
Rotary guide sensor does not turn on.
Poor contact in the
connector termi-
nals.
Check the connection of connector of the
rotary guide motor and the connector YC2
on the main front PWB, and the continuity
across the connector terminals. Repair or
replace if necessary.
Broken gears or
couplings of rotary
guide motor.
Replace rotary guide motor.
Defective rotary
guide motor.
Check for continuity across the coil. If none,
replace rotary guide motor.
Defective rotary
guide sensor.
Check if YC2-8 on the main front PWB goes
low when rotary guide sensor is turned off. If
not, replace rotary guide sensor.
Poor contact in the
connector termi-
nals.
Check the connection of connector of the
rotary guide sensor and the connector YC2
on the main front PWB, and the continuity
across the connector terminals. Repair or
replace if necessary.
Defective PWB. Main front PWB or engine PWB and check
for correct operation.
Code Contents
Remarks
Causes Check procedures/corrective measures