2JZ/2JX/2JV/2H7-1
1-5-11
1-5-3 Optical section
(1) Detaching and refitting the exposure lamp
Follow the procedure below to replace the exposure lamp.
Procedure
1. Remove the original platen or DP.
2. Remove the rear upper filter cover.
3. Remove nine screws and remove the rear
upper cover.
Figure 1-5-17
4. Open the front cover.
5. Remove the clip support.
6. Remove two screws and remove front left
cover 1.
Figure 1-5-18
Rear upper
filter cover
Screws
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Rear upper cover
Clip support
Screw
Screw
Front left
cover 1