U199
Displaying fuser heater temperature
Description
Displays the detected fuser temperature.
Purpose
To check the fuser temperature.
Method
1. Press the start key. The current setting is displayed.
*: 40/40, 50/40 ppm model only.
Completion
Press the stop key. The screen for selecting a maintenance mode No. is displayed.
U200
Turning all LEDs on
Description
Turns all the LEDs on the operation panel on.
Purpose
To check if all the LEDs on the operation panel light.
Method
1. Press the start key.
2. Select [ALL LED ON]. All the LEDs on the operation panel light.
3. Press the stop key. The LEDs turns off.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U201
Initializing the touch panel
Description
Automatically correct the positions of the X- and Y-axes of the touch panel.
Purpose
To automatically correct the display positions on the touch panel after it is replaced.
Method
1. Press the start key.
2. Select the [INITIALIZE] or [CHECK].
Method: [INITIALIZE]
1. Press the start key.
2. Press the center of the + keys. Be sure to press three + keys displayed in order.
The touch panel is adjusted automatically.
3. Press the indicated three + keys, and then check the display.
4. Press the stop key. The screen for selecting a maintenance item No. is displayed.
Method: [CHECK]
1. Press the start key.
2. Press the indicated three + keys, and then check the display.
When adjusting the display, press [INITIALIZE] to execute the adjustment automatically.
3. Press the stop key. The screen for selecting a maintenance item No. is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display Description
HEAT EDGE TEMP
Heat roller edge temperature (
°C)
HEAT CENTER TEMP
Heat roller center temperature (
°C)
PRESS TEMP*
Press roller center temperature (
°C)