2JZ/2JX/2JV/2H7
1-3-112
U411 3. Press [INPUT].
4. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [COMPLETE] is displayed. If a problem occurs
during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation stops.
Should this happen, determine the details of the problem and either repeat the procedure from the begin-
ning, or adjust the remaining items manually by running the corresponding maintenance items.
Method: DP(FACE DOWN)
1. Place the specified original for acquiring gamma target data (P/N: 303JX57010) on the platen, and
press the start key.
2. Place the specified original for acquiring matrix target data (P/N: 303JX57020) on the platen, and press
the start key.
When normally completed, [
COMPLETE
] is displayed.
3. Select the item (place all oroginals face down).
[INPUT]
1. Select [INPUT].
2. Place a specified original (P/N: 302AC68243).
3. Press the start key. Auto adjustment starts.
[GAMMA]
1. Select [MTF/GAMMA].
2. Place a specified original (P/N: 303JX57010).
3. Press the start key. Auto adjustment starts.
[MTF/MATRIX]
1. Select [MATRIX].
2. Place a specified original (P/N: 303JX57020).
3. Press the start key. Auto adjustment starts.
When [ALL] is selected, the adjustment of [INPUT], [MTF/GAMMA] and [MATRIX] can be executed at once.
When adjusting, place the three specified originals, and then press the start key.
Set the original 303JX57020, and then place 303JX57010 and 302AC68243 in order on the top of the orig-
inal.
When automatic adjustment has normally completed, [COMPLETE] is displayed. If a problem occurs
during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation stops.
Should this happen, determine the details of the problem and either repeat the procedure from the begin-
ning, or adjust the remaining items manually by running the corresponding maintenance items.
Completion
Press the stop key. The screen for selecting a maintenance item is displayed.
Maintenance
item No.
Description
Display Description
INPUT Automatic adjustment of first page using the DP for: original size mag-
nification/leading edge timing/center line.
Display Description Original to be used for
adjustment (P/N)
ALL Automatic adjustment of second page using the
DP for: original size magnification/leading edge
timing/center line, input gamma, chromatic
aberration filter, MTF filter and matrix.
302AC68243/303JX57010/
303JX57020
INPUT Automatic adjustment of second page using the
DP for: original size magnification/leading edge
timing/center line.
302AC68243
MTF/GAMMA Automatic adjustment of second page using the
DP for: MTF filter and input gamma.
303JX57010
MATRIX Automatic adjustment of second page using the
DP for: matrix.
303JX57020