2JZ/2JX/2JV/2H7
1-4-4
Paper
feed sec-
tion
17
Misfeed in paper
feeder horizontal
paper conveying
section 3
Paper path sensor 1 (PPS1) does not turn on within
specified time of the paper path sensor 2 (PPS2)
turning on (paper feed from 3000-sheet paper
feeder).
250 ms 250 ms 250 ms
18
Misfeed in vertical
paper conveying
section
The registration switch (RSW) does not turn on
within specified time of feed switch 1 (FSW1) turning
on.
1407 ms 1005 ms 844 ms
Feed switch 1 (FSW1) does not turn on within speci-
fied time of feed switch 2 (FSW2) turning on.
1040 ms 743 ms 624 ms
Feed switch 2 (FSW2) does not turn on within speci-
fied time of feed switch 3 (FSW3) turning on.
2133 ms 1524 ms 1280 ms
Feed switch 1 (FSW1) does not turn off within speci-
fied time of feed switch 2 (FSW2) turning off.
2040 ms 1457 ms 1224 ms
Feed switch 2 (FSW2) does not turn off within speci-
fied time of feed switch 3 (FSW3) turning off.
1133 ms 810 ms 680 ms
Feed switch 1 (FSW1) does not turn off within speci-
fied time of feed switch 2 (FSW2) turning on.
1040 ms 743 ms 624 ms
Feed switch 2 (FSW2) does not turn off within speci-
fied time of feed switch 3 (FSW3) turning on.
2133 ms 1524 ms 1280 ms
19
Misfeed in paper
feeder paper con-
veying section
Feed switch 3 (FSW3) does not turn on within speci-
fied time of PF feed switch (PFFSW) turning on.
1134 ms 810 ms 680 ms
21
Multiple sheets in
MP tray paper feed
section
The MP paper feed switch (MPPFSW) does not turn
off within specified time from start of paper feed.
1540 ms 1100 ms 924 ms
The MP paper feed switch (MPPFSW) does not turn
off within specified time of its turning on.
Paper
length +
1460 ms
Paper
length +
1043 ms
Paper
length +
876 ms
22
Multiple sheets in
cassette 1 paper
feed section
Feed switch 1 (FSW1) does not turn off within speci-
fied time from start of paper feed.
1713 ms 1224 ms 1028 ms
Feed switch 1 (FSW1) does not turn off within speci-
fied time of its turning on.
2380 ms 1700 ms 1428 ms
23
Multiple sheets in
cassette 2 paper
feed section
Feed switch 2 (FSW2) does not turn off within speci-
fied time from start of paper feed.
1800 ms 1286 ms 1080 ms
Feed switch 2 (FSW2) does not turn off within speci-
fied time of its turning on.
2467 ms 1762 ms 1480 ms
24
Multiple sheets in
cassette 3 paper
feed section
Feed switch 3 (FSW3) does not turn off within speci-
fied time of its turning on (paper feed from paper
feeder).
1136 ms 812 ms 682 ms
Feed switch 3 (FSW3) does not turn off within speci-
fied time of its turning on (paper feed from 3000-
sheet paper feeder).
2140 ms 2140 ms 2140 ms
25
Multiple sheets in
cassette 4 paper
feed section
The PF feed switch 1 (PFFSW) does not turn off
within specified time of its turning on.
1136 ms 812 ms 682 ms
Section Jam code Conditions
Specified time
25/25 ppm
30/30 ppm
40/40 ppm
50/40 ppm
Color
50/40 ppm
B/W