2JZ/2JX/2JV/2H7
1-4-7
Optional
DP
71
An original jam in
the original feed
section
The original registration switch (ORSW) does not
turn on within specified time of the original feed
switch (OFSW) turning on.
914 ms 557 ms 557 ms
72
An original jam in
the original con-
veying section
DP timing switch 1 (DPTSW1) turns off within the
specified time since the switch turns on.
914 ms 557 ms 557 ms
73
An original jam in
the original regis-
tration section
During single scanning, the DP timing switch 1
(DPTSW1) does not turn on within specified time of
the original registration switch (ORSW) turning on
(Retry 5 times).
1774 ms 1080 ms 1080 ms
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn on within specified
time of the original registration switch (ORSW) turn-
ing on (Retry 5 times).
1774 ms 1080 ms 1080 ms
During dual scanning, the DP timing switch 2
(DPTSW2) does not turn on within specified time of
the original registration switch (ORSW) turning on
(Retry 5 times).
1014 ms 617 ms 617 ms
74
An original jam in
the original feed
section
The original feed switch (OFSW) or original registra-
tion switch (ORSW) does not turn off within specified
time of the DP timing switch 1 (DPTSW1) turning
on.
2084 ms 1268 ms 1268 ms
Scanning of previous original is not complete when
DP timing switch 1 (DPTSW1) turns on.
---
75
An original jam in
the original con-
veying section
During single scanning, the DP timing switch 1
(DPTSW1) does not turn off within specified time of
the original registration switch (ORSW) turning off.
1416 ms 862 ms 862 ms
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn off within specified
time of the original registration switch (ORSW) turn-
ing off.
1416 ms 862 ms 862 ms
During dual scanning, the DP timing switch 2
(DPTSW2) does not turn off within specified time of
the original registration switch (ORSW) turning off.
656 ms 400 ms 400 ms
76
An original jam in
the original switch-
back section 1
During duplex switchback scanning, the switchback
tray switch (SBTSW) does not turn on within speci-
fied time of the DP timing switch 1 (DPTSW1) turn-
ing on.
2318 ms 1411 ms 1411 ms
77
An original jam in
the original switch-
back section 2
During duplex switchback scanning, the original reg-
istration switch (ORSW) does not turn on within
specified time since original switchback operation
starts.
935 ms 569 ms 569 ms
Section Jam code Conditions
Specified time
25/25 ppm
30/30 ppm
40/40 ppm
50/40 ppm
Color
50/40 ppm
B/W