922.xx error messages
Error code Description Action
922.00 Fuser hot roll failed to reach target departure. Go to
“Fuser (922.00, 922.25) failure service
check” on page 245.
922.02 The fuser hot roll does not reach the “beginning
lamp detection” parameter in the specified time.
Go to
“Fuser (922.02–922.04 and 922.06–
922.07) failure service check” on page 245.
922.03 The fuser hot roll does not reach the “final lamp
detection” parameter, but not in the specified time.
922.04 The fuser hot roll has timed out and not reached
the “final lamp detection” parameter during the
specified time.
922.05 After hot roll lamp detection, did not roll over to
steady state control in time.
The control code has gotten lost.
Go to
“Fuser hot roll control code service
check” on page 242.
922.06 The fuser hot roll did not reach operating
temperature within new enhanced control.
Go to
“Fuser (922.02–922.04 and 922.06–
922.07) failure service check” on page 245.
922.07 The fuser hot roll did not reach operating
temperature after increasing interpage gap.
922.25 Fuser hot roll failed to reach target departure. Go to
“Fuser (922.00, 922.25) failure service
check” on page 245.
922.27 The fuser hot roll does not reach the “beginning
lamp detection” parameter in the specified time.
Go to
“Fuser (922.27–922.29, 922.31–922.32)
failure service check” on page 246.
922.28 The fuser hot roll does not reach the “final lamp
detection” parameter, but not in the specified time.
922.29 The fuser hot roll has timed out and not reached
the “final lamp detection” parameter during the
specified time.
922.30 After hot roll lamp detection, did not roll over to
steady state control in time.
The control code has gotten lost.
Go to
“Fuser hot roll control code service
check” on page 242
922.31 The fuser hot roll did not reach operating
temperature within new enhanced control.
Go to
“Fuser (922.27–922.29, 922.31–922.32)
failure service check” on page 246.
922.32 The fuser hot roll did not reach operating
temperature after increasing interpage gap.