6 Remove the front duplex guide assembly.
Media out actuator removal
1 Remove the pick arm assembly. Go to “Pick arm assembly removal” on page 359.
2 Release the hook (A) securing the media out actuator to the unit.
A
3 Remove the media out actuator.
Option drive shaft removal
1 Gently place the printer on its left or right side.
2 Using pliers, gently pull the option drive shaft from the machine.