Sensor shield assembly removal
1 Remove the inner
deflector.
Go to “Inner
deflector
removal” on page 337.
2 Gently unsnap the sensor shield assembly from the machine.
A
3 Remove the sensor shield assembly.
Installation warning: When replacing the sensor shield assembly, ensure that the spring (A) is properly
aligned and the sensor shield assembly opens and closes properly.
Transfer roll assembly removal
1 Open the operator panel door assembly.
2 Remove the print cartridge.
3 Gently unsnap the transfer roll assembly from the machine.
7462
Repair information
351