EasyManua.ls Logo

Lexmark 7462 series - Scanner Unit Assembly Removal (Model X658)

Lexmark 7462 series
729 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scanner unit assembly removal (model X658)
Warning—Potential Damage: When replacing the system card assembly and the operator panel assembly,
make sure to:
Replace only one component at a time.
Perform a POR every after each component is replaced.
If this procedure is not followed, then the printer will be rendered inoperable.
These components can be used as a method of troubleshooting as long as the machine is booted into diagnostic
mode or is operating in diagnostic mode. Once a component has been installed in a machine and powered up
into user mode, it cannot be used in another machine. It must be returned to the manufacturer.
1 Remove the ADF unit assembly. Go to ADF unit assembly removal (model X658)” on page 561.
2 Remove the left side cover. Go to “Left side cover removal (model X658)” on page 318.
3 Remove the scanner controller card cage cover.
4 Disconnect the CCD and ribbon cable harnesses.
5 Remove the three screws (A) from the right side of the scanner support.
6 Remove the three screws (B) from the left side of the scanner support.
A
B
7 Slide the cover strip (C) to the left, and then remove using a prying tool.
7462
Repair information
533

Table of Contents

Related product manuals