High capacity input tray (HCIT) tray lift drive motor assembly removal
Note: Carefully remove the base machine from the HCIT tray assembly before proceeding.
1 Remove the HCIT cover, right. Go to “High capacity input tray (HCIT) cover, right removal” on page 421.
2 Remove the HCIT cover, left. Go to “High capacity input tray (HCIT) cover, left removal” on page 423.
3 Disconnect the HCIT tray lift drive motor cable connector from the HCIT controller card assembly.
Note: Remove the cable from the restraint, and observe the routing for reinstallation.
4 Remove the eight screws (A) securing the HCIT tray lift drive motor assembly.
A
A
5 Remove the HCIT tray lift drive motor assembly.